Water Temperature Controls
The temperature of water required in floor heating systems is less than that required
for radiators or stored hot water. If these other services are connected to the same
boiler it will be necessary to control the water temperature using one of the
Polyplumb water temperature control units.
Modulating Pump Unit (PB970014)
The modulating pump unit controls water temperatures
between 45°C and 60°C. The inclusion of a modulating
pump ensures that the flow to the floor heating circuits
is automatically adjusted to allow for the opening and
closing of actuators when individual room temperature
is required. The unit is suitable for manifolds
demanding up to 15Kw heat load.
The temperature of the water is set using the pilot
pin on the hand wheel. When the pilot pin is flush
with the hand wheel the temperature is set to 55°C.
Each click to + or – increases or decreases the
temperature by 1°C.
The modulating pump unit is fitted directly to the
manifold at either end by turning the pump through
180°. An additional zone valve is required when using
the modulating pump unit supplied by others.

Floor heating control pack (PB970015)
The pack controls water temperatures between 35°C
and 60°C, and incorporates a fixed head pump and a
22mm 2-port zone valve, which is suitable for
manifolds demanding up to 15Kw heat load. The set
temperature of the water is shown on the wheel head.
The control pack is fitted directly to the manifold at
either end, as both left hand and right hand connector
bends are supplied with the unit.
Dimensions of assembled unit
Note: The valves shown on this diagram are purchased
separately and not supplied with the unit.
Manifold bends (PB12735)
The water temperature control packs can be fitted
at 90° to the manifold using the manifold bends.
This allows manifolds and pump units to be corner
mounted where space is at a premium,
eg understairs cupboard.