Room Temperature Controls
A comprehensive range of room temperature control products compliments
Polyplumb floor heating systems. The control packs below are designed specifically
for floor heating, which is controlled differently to radiator systems.
Controlling floor heating
The control of floor heating systems is different to
that of conventional radiator systems, as the space
should not be allowed to cool completely during the
heating season. The temperature during unoccupied or
night time periods should fall to around 4°C lower than
the occupied temperature.
This lower temperature setting is known as the
set-back temperature, eg occupied temperature 21°C,
set-back temperature 17°C.
Individual room control
Polyplumb floor heating controls allow each room to
be individually controlled, through programmable room
thermostats and a master wiring centre, that when
connected to valve actuators (PB00401) allow each
room to have individual time and temperature settings.
As the desired room temperatures are achieved, the
actuators to those circuits will close. When all rooms
on a manifold are satisfied the manifold pump will stop,
the zone valve will close and the signal to the boiler will
be cut. As all individual rooms are heated only when
they are required the system ensures maximum
comfort and system efficiency.
The number of control zones you require will depend
on the number of rooms you wish to control
individually. The 4, 6 and 8 zone packs describe the
number of areas you wish to control, not necessarily
the number of circuits you are supplying from that
manifold. To optimise the use of each control pack you
will need to understand the following guidelines:
- The 4 zone pack contains 4 room thermostats, the
6 zone pack contains 6 room thermostats and the 8 zone pack contains 8 room thermostats.
- Each room thermostat can control 1 zone and up
to 4 actuators.
- Rooms over 40m2 should be allocated as 2 zones
and have 2 room thermostats.
- An actuator is required on each circuit that
requires control.
- Circuits serving small areas, WC’s, cloakrooms,
dressing rooms etc, can be installed as subservient
rooms, ie controlled by a room thermostat in the master room, eg hall and WC, bedroom and
dressing room.
Control equipment
The 4 zone master unit provides wiring connections for
the boiler (including volt free), zone valve, UFH pump,
and up to 4 programmable room thermostats (control
zones) and actuators (maximum 4 per zone). A 4 zone
master unit is required at each manifold.
The 4 zone slave unit simply plugs into the master unit
and provides additional connections where more than
4 programmable room thermostats (zones) are
required. Wiring connections for an additional 4
programmable room thermostats (zones) and
subsequent actuators are provided.
Programmable room thermostats (PBPRP)
The programmable room thermostat provides time and
temperature control in each zone.
Features include:
- 7 day programmer
- Set-back temperature setting
- Frost protection programme
- Holiday programme
- 5 pre-set programmes for easy set up
- No loss of programming when battery
change required
- Can be connected to wet room sensor (PB23020)
Wet Room Sensor (PB23020)
Where time and temperature control needs to be
applied to a bathroom or wet area, the wet area sensor
can be installed within the wet room and connected to
the programmable room thermostat installed in an
adjacent dry area.
The sensor is supplied with 3m of cable and can either
remain in the supplied housing and be wall mounted,
or removed from the housing and used as a floor
surface sensor.
Follow link to buy Water Control Packs on-line.
| Pack |
Single Zone |
4 Zone |
6 Zone |
8 Zone |
| Pack Code |
PB1ZP |
PB4ZP |
PB6ZP |
PB8ZP |
| Content |
|
|
|
|
| 4 Zone Master |
1 |
1 |
1 |
1 |
| 4 Zone Slave |
|
|
1 |
1 |
| Programmable Room Stat |
1 |
4 |
6 |
8 |
| Manifold 1 - A 4 zone pack would be required with 8 actuators |
| Room |
Number of Circuits |
Room Temperature Control Required |
Room Thermostats |
Actuators |
Wet Room Sensors |
| Lounge |
3 |
Yes |
1 |
3 |
0 |
| Dining |
2 |
Yes |
1 |
2 |
0 |
| Kitchen |
1 |
Yes |
1 |
1 |
0 |
| Hall |
1 |
Yes |
1 |
1 |
0 |
| WC |
1 |
Off hall thermostat |
0 |
1 |
0 |
| |
|
Total |
4 |
8 |
0 |
| Manifold 2 - A 6 zone pack would be required with 8 actuators & 3 wet room sensors |
| Room |
Number of Circuits |
Room Temperature Control Required |
Room Thermostats |
Actuators |
Wet Room Sensors |
| Bedroom 1 |
2 |
Yes |
1 |
2 |
0 |
| Bedroom 2 |
1 |
Yes |
1 |
1 |
0 |
| Bedroom 3 |
1 |
Yes |
1 |
1 |
0 |
| Bedroom 4 |
1 |
Yes |
1 |
1 |
0 |
| Bathroom |
1 |
Yes |
1 |
1 |
1 |
| En suite 1 |
1 |
Yes |
1 |
1 |
1 |
| En Suite 2 |
1 |
Yes |
1 |
1 |
1 |
| |
|
Total |
6 |
8 |
3 |
Examples (1 & 2) : material scheduling for typical four bedroom property
|