Trading Depot supplies the Main 24HE Combi Boiler. It has all the features of the Main Combi plus a second heat exchanger neatly tucked into the same size case for the added benefit of lower running costs. It simply extracts more heat from a given amount of gas. The Main Combi 24 and 30 HE are rated SEDBUK Band B of the Government's energy efficiency rating scheme.

Technical Data

Controls
User adjustable CH temperature   Yes
User adjustable DHW temperature   Yes
Operating mode selector switch   Yes
LED operating / fault status display   Yes
Integral 24 hr electro-mechanical timer   Optional
Integral 7 day electronic timer   Optional
Gas
Natural gas   Yes
Optional LPG conversion kit   Yes
Inlet supply pressure (Natural gas) mbar 20
Inlet supply pressure (Propane) mbar 37
Gas rate m3/hr 2.62
Heat input (maximum) kW 24.8
Heat input (minimum) kW 10.6
Heat output maximim non-condensing kW 24
Heat output minimum non-condensing kW 9.8
Heat output maximum condensing kW 25.2
Heat output minimum condensing kW 10.1
Domestic hot water flow rate (maximum) @ 35°C rise litres/min 9.8
Domestic hot water flow rate (minimum) litres/min 2.5
Seasonal efficiency band SEDBUK B
NOx Class 3
Electrical
Electrical supply Volts / Hz 230 / 50
Power consumption Watts 170
External fuse rating Amps 3
Ingress protection rating (as supplied)   IPX5D
Pump overrun   No
24hr pump exercise   No
Integral frost thermostat (boiler protection only)   No
Weight
Installation lift weight kg 43.5
Mechanical & Hydraulic
DHW system pressure maximum bar 8
DHW operating pressure minimum bar 0.2
Safety pressure discharge bar 3
Integral automatic bypass   Yes
CH system capacity maximum litres 125
Gas supply pipe size mm 22
Flow & return pipe size mm 22
Temporary filling loop   Optional
Compartment ventilation required   No
Pre-plumbing jig   No
Flue Systems
Standard concentric flue diameter mm 100
Standard flue installed length mm 685
Maximum equivalent length horizontal m 4
Maximum equivalent length vertical m 4
Optional twin pipe vertical flue diameter mm 80 / 80
Maximum equivalent length m 12

Follow the link to buy the Main 24HE Combi Boiler on-line now.