Manrose XF100 / XP100 / WF100
The Manrose range of 100mm (4") Bathroom/ Toilet Fans incorporates the latest technology and design and offers the most comprehensive range with the widest choice of options and variations.
Attractively styled in high gloss ABS thermoplastics for modern appearance and ease of cleaning, designed for easy installation and can be wall, ceiling or window mounted.
There are several options available; Standard model for remote switching, integral Pullcord units, and Timer models which incorporate an electronic time delay switch. Humidistat Control models are also available which are designed to switch on the fan as the humidity rises in the bathroom and off as it drops. The Passive Infra-Red model is sensitive to movement and will switch on the fan when someone enters a room and switch it off when the room is vacated.
Key features includes:
- Extract rate 85m³hr, 23 litres per second
- Available in seven options
- British made
- Designed to exceed the 1995 Building Regulations on Ventilation (F1)
- Tested to comply with HD280/BS3456 Part 102:342 1988
- XF100 style also available in 5" (XF120) and 6" (XF150B) versions
- Full back up range of ventilation accessories
- 2 year no quibble guarantee
- BEAB approved
- Rated to IP44
Technical Data
100mm (4") Wall/Ceiling Fans
| Catalogue No. |
Type |
| XF100S |
Standard model for remote switching. |
| XF100P |
As above supplied with pullcord switch. |
| XF100T |
Timer model incorporating integral adjustable electronic timer (adjustable 1-20 mins). |
| XF100TP |
As above but with pullcord override switch. Requires no switched live. |
| XF100H |
Humidity control fitted with our new 2 speed option as standard. The fan will run at full speed on integral or remote switching but will run at about half speed when humidity rises over the pre-set level which is adjustable between 40% RH and 95% RH. Complete with integral adjustable timer (adjustable 1-20 mins). Secondary speed is also adjustable. |
| XF100HP |
As above but with pullcord override switch. Requires no switched live. |
| XF100PIR |
PIR activated model with adjustable timer which switches on as a person enters the room and runs on after the room is vacated. There is no need to connect to a separate switch. Timer adjustable between 1-20 mins. Requires no switched live. |
100mm (4") Extractor Paks
with aluminium flexible ducting and wall grille
| Catalogue No. |
Type |
| XF100S |
Standard model for remote switching. |
| XF100P |
As above supplied with pullcord switch. |
| XF100T |
Timer model incorporating integral adjustable electronic timer (adjustable 1-20 mins). |
| XF100TP |
As above but with pullcord override switch. Requires no switched live. |
| XF100H |
Humidity control fitted with our new 2 speed option as standard. The fan will run at full speed on integral or remote switching but will run at about half speed when humidity rises over the pre-set level which is adjustable between 40% RH and 95% RH. Complete with integral adjustable timer (adjustable 1-20 mins). Secondary speed is also adjustable. |
| XF100HP |
As above but with pullcord override switch. Requires no switched live. |
| XF100PIR |
PIR activated model with adjustable timer which switches on as a person enters the room and runs on after the room is vacated. There is no need to connect to a separate switch. Timer adjustable between 1-20 mins. Requires no switched live. |
100mm (4") Window Fans
| Catalogue No. |
Type |
| WF100P |
Pullcord model. |
| WF100T |
Timer model incorporating integral adjustable electronic timer (adjustable 1-20 mins). Complete with pullcord switch. |
| WF100H |
Humidity control fitted with our new 2 speed option as standard. The fan will run at full speed on integral or remote switching but will run at about half speed when humidity rises over the pre-set level which is adjustable between 40% RH and 95% RH. Complete with integral adjustable timer (adjustable 1-20 mins). Secondary speed is also adjustable. |
| WF100PIR |
PIR activated model with adjustable timer which switches on as a person enters the room and runs on after the room is vacated. There is no need to connect to a separate switch. Timer adjustable between 1-20 mins. Requires no switched live. |
Construction
These fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability and finish.
Electrical
220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.
Motor
Single phase induction motor with pre-oiled bearings fitted for a long maintenance free life and protected by a thermal fuse.
Guarantee
Two year no quibble guarantee.
Installation
XF100 Series designed to be mounted on walls or ceilings (Pullcord models wall mounting only) through 100mm (4") diameter flexible or rigid pipes. Also suitable for use with the Manrose low profile flat channel ducting systems.
XP100 Series designed for through wall fixing and comes complete with aluminium flexible ducting and external wall grille.
WF100 Series designed for window mounting through a standard 115-155mm ø hole.
Performance
The extract rate of all models is 85m³hr, 23 litres per second.
Packaging
XF100 Series in outers of 10 measuring 370mm x 200mm x 560mm and weighs 7 kgs.
XP100 Series in outers of 10 measuring 380mm x 210mm x 765mm and weighs 9 kgs.
WF100 Series in outers of 10 measuring 360mm x 210mm x 570mm and weighs 9 kgs.
Additional Data
Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
Sound volume: 41.0 dB(A) Maximum operating temperature 40° C. |