Mira Elite STMira Elite ST Electric Shower

Designed to work off a gravity-fed system, the Mira Elite ST is ideal for areas where mains water pressure is either too low or erratic to operate a standard electric or mixer shower. With a built in pump to boost the cold water supply, the Mira Elite ST produces consistent water delivery anytime.

Mira elevate Electric ShowerDescription

Mira Elite ST- 9.8kW

240V AC 9.8kW, (230V AC 9.0kW) heater with a Mira Logic Adjustable spray showerhead with four different spray actions (Start, Soothe, Force and Eco). Individual lights indicate 'Power' and 'Low Flow'. Supplied complete with hose, clamp bracket, slide bar and integrated hose retaining ring and soap dish.

Limitations of Use

Mira Elite STTemperature

Pressure

Accessories

Optional DCV-H: outlet double check valve providing an alternative method of complying with UK water regulations

Guarantee

Guaranteed for two years from date of purchase against faulty materials or workmanship. Optional extended warranty available. Contact Mira Customer Support.

Application

The Mira Elite ST is suitable for installation as part of the following plumbing systems:

Installation - Plumbing

Surface-mounted unit

Inlet connection : 15mm inlet compression connector which swivels to accept plumbing supplies from the top, bottom or back

Outlet connection : 1/2" BSP male

The plumbing installation must comply with the requirements of UK water Regulations / Bylaws (Scotland), Building Regulations / Bylaws (Scotland) Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers.

The installation should be carried out by a plumber or a contractor who is registered or is a member of an association

Protect the product from damage whilst making soldered connections. Some fluxes cause damage to plastic components

This product must have its own separate supply from the cold water storage cistern, avoiding any other draw-offs, long horizontal pipe runs and 90o elbows

Installation - Electrical

The appliance must be earthed

This appliance is intended to be permanently connected to the fixed electrical wiring of the mains system, in accordance with the current edition of the 'The Plugs and Sockets etc. (Safety) regulations in force at the time of installation.

The appliance requires a 45 Amp supply fuse

The terminal block will not accept cable larger than 16mm2

Maximum ambient air temperature for the appliance whilst in use is 30oC

The appliance will provide satisfactory performance with an incoming electrical supply voltage of 230V ±10%. The supply voltage will affect the flow rate.

The installation must comply with 'Requirements for Electrical Installations' (commonly referred to as the IEE Wiring Regulations) or any particular regulations and practices specified by the local electricity supply company.

A separate, permanently connected supply must be taken from the consumer unit to the appliance via a double pole switch with at least a 3mm contact separation.

The switch can be a ceiling-mounted pull-cord switch or a wall mounted switch in the appropriate zone (see Wiring regulations)

We recommend the inclusion of a 30mA residual current device (RCD). This may be a requirement of Wiring Regulations.