Mira Advance ATL / Memory

The Mira Advance ATL 8.7kW and 9.8kW

240V AC 8.7kW (230V AC 8.0kW) or 240V AC 9.8kW (230V AC 9.0kW) heater with Mira Logic adjustable spray showerhead, providing four different spray actions (Start, Soothe, Force and Eco). Individual lights indicate 'Flow', 'Low Pressure' and 'Service'. Supplied complete with metal hose, clamp bracket, soap dish, slide bar which can be corner mounted and hose retaining ring.

The Mira Advance ATL Thermostatic electric shower with a maximum temperature stop, can be adjusted to eight different maximum temperatures providing safety, flexibility and precise temperature control.

Mira Electric Shower : Advance ATL MemoryMira Advance ATL Memory 8.7kW & 9.8kW

240V AC 8.7kW (230V AC 8.0kW) or 240V AC 9.8kW (230V AC 9.0kW) heater with Mira Logic adjustable spray showerhead, providing four different spray actions (Start, Soothe, Force and Eco). Individual lights indicate 'Flow', 'Low Pressure' and 'Service'. Supplied complete with metal hose, clamp bracket, soap dish, slide bar which can be corner mounted and hose retaining ring.

The Mira Advance ATL Memory Thermostatic electric shower with a maximum temperature stop, can be adjusted to eight different maximum temperatures providing safety, flexibility and precise temperature control. Includes five memory buttons to allow the user to pre-set five choices of flow level and temperature, which can be easily recalled by pressing the appropriate button.

Description

Technical Information

Limitations of Use

Temperature

The Mira Advance ATL works by regulating the flow of water, minimum 0.5 bar (maintained) pressure, over the heating elements contained in the heater tank of the shower unit.

A maintained pressure of 1.0 bar is required for the Mira Advance ATL to operate at optimum power output.

The showering temperature is adjusted by turning the temperature control knob which varies the flow of cold water across the elements. The slower the rate of flow, the warmer the water and vice versa.

Spray plates in shower handsets should always be kept clean to maintain a consistent flow and assist in temperature control.

The Mira Advance ATL is a thermostatic electric shower which will compensate for:

The set temperature is controlled typically to within ±1oC

Maximum temperature is set at 48oC but can be reset to eight different maximum temperatures from 37oC to 48oC

Allows three flow settings at the same temperature

When the shower if first turned on or a different temperature is selected, there will be a slight delay before the shower temperature changes, to allow the previously heated water to be used up.

Pressure

Accessories

Optional DCV-H: outlet double check valve providing an alternative method of complying with UK water regulations

Guarantee

Guaranteed for two years from date of purchase against faulty materials or workmanship. Optional extended warranty available. Contact Mira Customer Support.

Application

The new Mira Advance ATL is suitable for installation as part of the following plumbing systems:

Installation - Plumbing

Surface-mounted unit

Inlet connection : 15mm plastic swivel stub for use with a compression fitting (not supplied) from the top, bottom or back.

Outlet connection : 1/2" BSP male

The plumbing installation must comply with the requirements of UK water Regulations / Bylaws (Scotland), Building Regulations / Bylaws (Scotland) Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers. The installation should be carried out by a plumber or a contractor who is registered or is a member of an association

Protect the product from damage whilst making soldered connections. Some fluxes cause damage to plastic components

Installation - Electrical

The appliance must be earthed

This appliance is intended to be permanently connected to the fixed electrical wiring of the mains system, in accordance with the current edition of 'The Plugs and Sockets etc. (Safety) regulations' in force at the time of the installation.

The appliance required:

a. 45Amp supply fuse (9.8kW)

b. 40 Amp supply fuse (8.7kW)

The terminal block will not accept cable larger than 16mm2

Maximum ambient temperature for the appliance whilst in use is 30oC

The appliance will provide satisfactory performance with an incoming electrical supply voltage of 230V ±10%. The supply voltage will affect the flow rate.

The installation must comply with 'Requirements for Electrical Installations' (commonly referred to as the IEE Wiring Regulations) or any particular regulations and practices specified by the local electricity supply company.

A separate, permanently connected supply must be taken from the consumer unit to the appliance via a double pole switch with at least a 3mm contact separation.

The switch can be a ceiling-mounted pull-cord switch or a wall mounted switch in the appropriate zone (see Wiring regulations)

We recommend the inclusion of a 30mA residual current device (RCD). This may be a requirement of Wiring Regulations.

Click to view our full range of Mira Advance ATL / Memory Shower available to buy on-line.